Scores:
9
MNiSW
79.88
ICV
 
 

COMPARISON OF MANGANESE REMOVAL EFFICIENCY OF WATER ON SELECTED POROUS FILTER BEDS

Agnieszka Kisło 1  ,  
 
1
Politechnika Białostocka, ul. Wiejska 45A, 15-351 Białystok
Inż. Ekolog. 2017; 4:13–19
Publish date: 2017-08-01
KEYWORDS:
TOPICS:
ABSTRACT:
According to the Health Regulations of 20 April 2010, the concentration of manganese in water must not exceed 0.05 mg/l. This condition forces underground water treatment and the required concentrations. For this purpose, popular filter materials are available on the domestic market. Authors in the study conducted experiments on two filter beds. The first was the G-1 catalytic mass, the second was the Crystal-Right. Thus, this paper presents the methodology of the study, the characteristics of the studied fields and the results of water tests, including the content of manganese in the process after filtration.
CORRESPONDING AUTHOR:
Agnieszka Kisło   
Politechnika Białostocka, ul. Wiejska 45A, 15-351 Białystok